BITEC Inc Morrilton AR. |
NC |
BITEC |
Insulation: Various Base Sheet: 1 or more plies Type G-2 Membrane: APM-4.5T, APS-4T, ISA-4T |
1-1/2 |
#97 or #97AF (1-1/2gal/sq) |
A |
| |
NC |
BITEC |
Insulation: Various Base Sheet: 1 or more plies Type G-2 Membrane: SPS-3H, SPM-3.5H, SFM-3.5H, SFM-3H |
3/4" |
#97 or #97AF (1-1/2gal/sq) |
A |
| |
NC |
BITEC |
Insulation: Various Base Sheet: 1 or more plies Type G-2 Membrane: SPM-4.5T |
3/4" |
#97 or #97AF (1-1/2gal/sq) |
A |
| |
NC |
BITEC |
Insulation: None Base Sheet: 2 plies Type G-2 Membrane: APM-4.5T, APS-4T, ISA-4T SPM-4.5T |
1/2" |
#97 or #97AF (1-2gal/sq) |
A |
| |
NC |
BITEC |
Insulation: None Base Sheet: 3 plies Type G-2 Membrane: APM-4T, APM-4.5T, APS-4T, ISA-4T |
1" |
#97 or #97AF (1-2gal/sq) |
A |
| |
NC |
BITEC |
Insulation: Various Base Sheet: 1 or more plies Type G-2 Membrane: SPS-3H, SPM-3.5H, SFM-3.5H, SFM-3H |
3/4" |
#97 or #97AF |
A |
| |
NC |
BITEC |
Insulation: None Membrane: SPS-3H, SPM-3.5H, SFM-3.5H,SFM-3H |
1/2" |
#97 or #97AF (1-2gal/sq) |
A |
| |
C-15/32 |
BITEC |
Insulation: (Optional) Base Sheet: 3 plies Type G-2 Membrane: APM-4T, APM-4.5T, APS-4T, ISA-4T, SPM-4.5T |
1/2" |
#97 or #97AF (1-2gal/sq) |
A |
| |
C-15/32 |
BITEC |
Insulation: Various/2 or more layers Base Sheet: 1 or more plies Type G-2 Membrane: APM-4T, APM-4.5T, APS-4T,ISA-4T, SPM-4.5T, SFM-3H, SFM-3.5H, SPM-3.5H, SPS-3H |
1/4" |
#97 or #97AF (1-2gal/sq) |
A |
| |
NC |
BITEC |
Insulation: Insulating Concrete Base Sheet: 1 or more plies Type G-2 Membrane: APM-4T, APM-4.5T, APS-4T |
1" |
#97 or #97AF (1-1/2gal/sq) |
A |
| |
C-15/32 |
BITEC |
Insulation: Any UL approved insulation Base Sheet: Type G-2, Hot Mopped Membrane: APM-4T, APM-4.5T, APS-4T, ISA-4T, SPM-4.5T |
1" |
#97 or #97AF (1-2gal/sq) |
A |
| |
C-15/32 |
BITEC |
Insulation: Various/2 min layers 3" min Base Sheet: Type G-2 Membrane: APM-4T, APM-4.5T, APS-4T, ISA-4T, SPM-4.5T, SFM-3H, SFM-3.5H, SPM-3.5H, SPS-3H |
1/2" |
#97 (1-2gal/sq) |
B |
| |
C-15/32 |
BITEC |
Insulation: NONE Base Sheet: 2 plies Type G-2 Membrane: APM-4T, APM-4.5T, APS-4T, ISA-4T, SPM-4.5T, SFM-3H, SFM-3.5H, SPM-3.5H, SPS-3H |
1/2 |
#97 (1-1/2gal/sq) |
B |
| |
NCRC |
BITEC |
Existing: BUR, A,B or C, S or G Membrane: APM-4T, APM-4.5T, APS-4T,ISA-4T, SPM-4.5T, SFM-3H, SFM-3.5H, SPM-3.5H, SPS-3H |
1/2" |
#97 or #97AF (1-1/2gal/sq) |
A |
| |
C-15/32 RC |
BITEC |
Existing: BUR, A,B or C, S or G(remo) Membrane: APM-4T, APM-4.5T, APS-4T,ISA-4T, SPM-4.5T, SFM-3H, SFM-3.5H, SPM-3.5H, SPS-3H |
1/2" |
#97 (1-1/2gal/sq) |
A |
| |
NCRC |
BITEC |
Existing:BUR,A,B or C, Grav part/remo Base Sheet: Type G-2 Membrane: APS-4T, ISA-4T |
1/2" |
#97 (1-1/2gal/sq) |
A |
| |
Struct. Cement- FiberRC |
BITEC |
Existing: BUR, A,B or C, S or G Base Sheet: Type G-2 Membrane: APM-4T, APM-4.5T, APS-4T, ISA-4T, SPM-4.5T, SFM-3H, SPM-3.5H |
1/2 |
#97 (1-1/2gal/sq) |
A |
| |
NCRC |
BITEC |
Existing: BUR, A,B or C, S or G Insulation: EPS/Overlaid WF or Perlite Base Sheet: Type G-2 Membrane: APM-4T, APM-4.5T, APS-4T,ISA-4T, SPM-4.5T, SFM-3H, SPM-3.5H |
1/2" |
#97 (1-1/2gal/sq) |
A |
| |
NCRC |
BITEC |
Existing: BUR, A,B or C, S or G Base Sheet: (Optional) Membrane: APM-4T, APM-4.5T, APS-4T,ISA-4T, SPM-4.5T, SFM-3H, SFM-3.5H,SPM-3.5H, SPS-3H |
1/2" |
#97 (1-1/2gal/sq) |
B |
BITEC RFG. of Canada, Inc. Quebec,Canada |
NC |
BITEC |
Insulation: Perlite, GlassFiber, W.F. Base Sheet: Type G-2 Membrane: Elastoplan 180 G/P, 180 G/S |
1-1/2" |
#97 (1-1/2gal/sq) |
A |
| |
NC |
BITEC |
Insulation: Perlite, GlassFiber, W.F. Base Sheet: Type G-2 Membrane: Elastoplan 250 G/P, 250 G/S |
3/4" |
#97 (1-1/2gal/sq) |
A |
Bitufa BV 7336 AR Apeldoorn Netherlands |
NC |
Bitufa BV |
Insulation: Perlite, GlassFiber, W.F., ISO Base Sheet: (Optional) Unibase Membrane: Flexoper N5, S5, Flexobit |
1/2" |
#97 (1-1/2gal/sq) |
A |
| |
NC |
Bitufa BV |
Insulation: Perlite, GlassFiber, W.F., ISO
Base Sheet: (Optional) Unibase Membrane: Flexoper MF5N, MF5S |
1" |
#97 (1-1/2gal/sq) |
A |
| |
NC |
Bitufa BV |
Insulation: Perlite, GlassFiber, W.F., ISO Base Sheet: Type G-1 or G-2 Membrane: Flexoper N5, S5, Flexobit |
1/2" |
#97 (1-1/2gal/sq) |
A |
| |
NC |
Bitufa BV |
Insulation: Perlite, GlassFiber, W.F., ISO Base Sheet: Type G-1 or G-2 Membrane: Flexoper MF5N, MF5S |
1" |
#97 (1-1/2gal/sq) |
A |
BMCA Insulation Products, Inc. Ontario, CA. |
NC M & R |
Premaflex |
Existing Roof System: A, B or C (gravel may be removed) Base Sheet: Type G-3 invverted Membrane: Permalite Permaflex RS, Peragrip RS |
1" |
#169 (Optional) (1 gal/sq) |
A |