Specification & Codes

Complete Karnak U.L. & F.M. Approved Systems Listing

Company Index




A : B : C : D : E : F : G : H : I : J : K : L : M : N : O : P : Q : R : S : T : U : V : W : X : Y : Z

Company Deck
Type
Membrane
Manufact.
System INC. Surfacing
Coating
U.L.
Class
MB Technology
Corp.Fresno,CA.
NC Fastorch Insulation: (Optional) WF, GF, Perlite
Base Sheet: (Optional) Type G-1, G-2
Membrane: FASTORCH SBS 160 mil, 160 mil
granule, or SUPERFLEX 160 mil granule
1/2" #97
(1-1/2 gal/sq)
A
  NC Fastorch Insulation: GF, Perlite 3/4"" to 1-1/2"
Base Sheet: 1 or more layers TypeG-1,G-2
Membrane: FASTORCH SBS 160 mil, 160 mil granule, or SUPERFLEX 160 mil granule
1/4" #97
(1-1/2 gal/sq)
A
Nord Bitumi US
Macon, GA.
NC NORD Insulation: (Optional) WF, GF, Perlite
Base Sheet: Type G-2
Membrane: Nord Poly NP-4B,4M,5B,Nord-200
2" #97 or #97AF
(1 to 2 gal/sq)
A
  NC NORD Insulation: (Optional) WF,GF,Perlite,ISO
Base Sheet: Type G-2
Membrane: Nord Poly NP-4B,4M,5B,Nord-200
EM-4000, Nordflex S, Ultra S, M, 170
1" #97 or #97AF A
  C-15/32 NORD Barrier Board: Water Resist. 1/2 Gypsum
Insulation: (Optional) WF,GF,Perlite,ISO
Base Sheet: Type G-2
Membrane: Nord Poly NP-4B,4M,5B,Nord-200 EM-4000, Nordflex S, M, Ultra S, M, 170
1" #97 or #97AF
(1-1/2 gal/sq)
A
  NC NORD Base Sheet: Type G-2
Membrane: Nord Poly NP-4B,4M,5B,Nord-200 EM-4000, Nordflex S, 170, Ultra S,
1" #97 or #97AF
(1-1/2 gal/sq)
A
  C-15/32 NORD Base Sheet: 2 plies Type G-2
Membrane: Nord Poly NP-4B,4M,5B,Nord-200
EM-4000, Nordflex S, 170, Ultra S,
1/4" #97 or #97AF
(2 gal/sq)
A
  C-15/32 NORD Insulation: ISO, ISO/Perlite composite
Base Sheet: Type G-2
Membrane: Nord Poly NP-4B,4M,5B,Nord-200 EM-4000, Nordflex S, 170, Ultra S,
1/2" #97 or #97AF
(2 gal/sq)
A
  C-15/32 NORD Insulation: GF 1-1/2"
Base Sheet: Type G-2
Membrane: Nord Poly NP-4B,4M,5B,Nord-200 EM-4000, Nordflex S, M, 170, Ultra M
1/4" #97 or #97AF
(2 gal/sq)
B
  C-15/32 NORD Base Sheet: 1 or more plies Type G-2
Membrane: Nord Poly NP-4B,4M,5B,Nord-200 EM-4000, Nordflex S, M, or Ultra
1/2" #97 or #97AF
(1-1/2-2gal/sq)
B
  C-15/32 NORD Insulation: ACFoam II 1.2""min.
Base Sheet: 1 or more plies Type G-2
Membrane: Nord Poly NP-4B, 4M, Nord-200 EM-4000, Nordflex S, M, or Ultra
1/2" #97 or #97AF
(1-1/2-2gal/sq)
B
  C-15/32 NORD Insulation: ISO. 1.2""min.
Insulation: WF, GF, Perlite, 1/2"
Membrane: Nord Poly NP-4B, 4M, Nord-200 EM-4000, Nordflex S, M, or Ultra
1" #97 or #97AF
(1-1/2-2gal/sq)
B
  C-15/32 NORD Insulation: ISO, ISO/Perlite composite
Base Sheet: Type G-2
Membrane: Nord Poly NP-4B,5B,4M,Nord-200
EM-4000, Nordflex S, M, 170, or Ultra M
1/2" #97 or #97AF
(1-1/2 gal/sq)
B
  C-15/32
M & R
NORD Existing System: Class A, B, C
(Gravel may be removed)
Insulation: (Optional) Various
Membrane: Nord Poly NP-4B,5B,4M,Nord-200
EM-4000, Nordflex S, M, 170, or Ultra M
1/2" #97 or #97AF
(1-1/2 gal/sq)
B
  C-15/32
M & R
NORD Existing System: Class A, B smooth BUR
(Gravel may be removed)
Insulation: (Optional) Various
Base Sheet: 1 or more pliesType G-2 or Multiple layers Type G-1
Membrane: Nord Poly NP-4B,5B,4M,Nord-200 EM-4000, Nordflex S, M, 170, or Ultra M
1/2" #97 or #97AF
(1-1/2 gal/sq)
B

Translate Site

Kanopy Reflective Roof Maintenance Solutions
  • Reduce Energy Use
  • Lowers Peak Energy Use, reducing energy costs year-round
  • Helps the environment, reduces "Heat Island Effect"
  • Extend the life of the roof
  • Reduces waste. Helps avoid roof tear-off.
  • Economic compared to roof replacement
  • Eliminates interior building operation disruption