529 Renu-White is a polymer acrylic based elastomeric roof coating that affords the building owner the energy saving benefits of a highly reflective white coating while providing good resistance to UV degradation and the weather. This economical coating forms a highly elastic membrane to protect a variety of roof substrates.
275 gallon totes
55 gallon drums
5 gallon pails
Reflective, co-polymer acrylic roof coating
Excellent choice for re-coating existing acrylic coated roofs
Reflective, co-polymer acrylic roof coating
Excellent choice for re-coating existing acrylic coated roofs
ASTM D 6083 Type II
Solar Reflectance: 0.85 Initial / 0.73 3-Yr. Aged
Thermal Emittance: 0.90 Initial / 0.88 3-Yr. Aged
SRI: 107 Initial / 90 3-Yr. Aged
529 Renu-White is designed for application over built-up roof (BUR) surfaces that have aged aluminum of 90 days, SBS and APP granular and smooth modified membranes that have weathered aluminum of 30 days, aged aluminum coated roofs as well as metal roofs. Also, may be applied to above grade vertical surfaces such as concrete, concrete block, brick, stucco and wood. 529 Renu-White maybe used for application over applicable base coats 405 Bond-N-Shield, 406 Tru-Grip, 404 Corrosion Proof Base and 407 EPDM & SPF as a base coat for EPDM.
Weight per Gallon: 11.5 lbs.
Solids by Weight: 63%, Nominal
Solids by Volume: 50%, Nominal
Elongation: 450%, Nominal ASTM D 412
Tensile Strength: 140 PSI, Nominal ASTM D 412
Cure Time: 24 to 48 hours @ 77°F and 50% Relative Humidity
Application Temp.: 40°F to 120°F
Service Temp(Cured Film): 15°F to 180°F
VOC Content: 40 g/L MAX
SURFACE PREPARATION:
All surfaces to be coated should be in sound condition and thoroughly cleaned and free of oil, grease, dust, dirt, debris and loose coating. Pressure wash with 799 Wash-N-Prep Roof Cleaner and water. Rinse surfaces well to remove all soapy residues and allow to dry completely. Metal surfaces must be wire brushed down to clean and stable surface. Repair all roof surfaces with appropriate materials prior to coatings. Read the SDS before using. For questions regarding repairs, surface preparation, or request for an SDS, please contact KARNAK Technical Services at 800-526-4236.
APPLICATION:
Recommended use is for application over one of KARNAK’s 400 series substrate-specific base coats or directly to the substrate in a two-coat application. Mix lightly prior to application of the coating. 529 Renu-White may be applied by brush, spray equipment or roller. Allow first coat to dry 8 to12 hours before application of the second coat. Apply each coat in one direction with the second coat applied perpendicular to the first/base coat. Apply when temperatures are 40ºF and rising but not over 120ºF. Do not apply when rain is expected during or within 24 hours after application. For applications in higher temperatures (above 90 °F) KARNAK recommends application in multiple thin coats to prevent trapped moisture problems. Commencement of work by the contractor implies his approval of the deck surface.
ROLLER / BRUSH APPLICATION:
Apply with a 3/4" – 1-1/4” nap roller or soft roof brush perpendicular to the first coat/base coat for proper protection.
SPRAY APPLICATION:
Utilize a heavy-duty professional airless spray pump. Equipment manufacturer should be consulted for more complete information. Spray application should be done with a 50% overspray pattern.
COVERAGE RATE:
Apply 529 Renu-White in two coats at the rate of 1.5 gallons per 100 sq. ft. (24 wet mils) per coat for a total coverage of 3 gallons per 100 sq. ft. or apply at the rate of 1.5 gallons per 100 sq. ft. over applicable KARNAK 400 series base coat. Do not thin coating. Coverage varies with their regularity and porosity of the roof surface.
ARCHITECTURAL COLORS:
White
Do not apply when rain is imminent. Do not take internally. If swallowed, do not induce vomiting. Call a physician immediately. Keep away from children. Use with adequate ventilation. Avoid prolonged contact with skin. Wash exposed areas promptly with soap and water. Flush eyes with copious amounts of water. Protect from freezing. Product must be dried before exposure to water. Do not thin. Store in a cool, dry place. Dispose of in an environmentally safe manner.
CARE OF TOOLS:
Clean tools with cool, soapy water immediately after use. Dry coating may be cleaned with mineral spirits or similar solvent. Take necessary precautions when handling combustible materials.
Reflective, co-polymer acrylic roof coating
Excellent choice for re-coating existing acrylic coated roofs
ASTM D 6083 Type II
Solar Reflectance: 0.85 Initial / 0.73 3-Yr. Aged
Thermal Emittance: 0.90 Initial / 0.88 3-Yr. Aged
SRI: 107 Initial / 90 3-Yr. Aged
529 Renu-White is designed for application over built-up roof (BUR) surfaces that have aged aluminum of 90 days, SBS and APP granular and smooth modified membranes that have weathered aluminum of 30 days, aged aluminum coated roofs as well as metal roofs. Also, may be applied to above grade vertical surfaces such as concrete, concrete block, brick, stucco and wood. 529 Renu-White maybe used for application over applicable base coats 405 Bond-N-Shield, 406 Tru-Grip, 404 Corrosion Proof Base and 407 EPDM & SPF as a base coat for EPDM.
Weight per Gallon: 11.5 lbs.
Solids by Weight: 63%, Nominal
Solids by Volume: 50%, Nominal
Elongation: 450%, Nominal ASTM D 412
Tensile Strength: 140 PSI, Nominal ASTM D 412
Cure Time: 24 to 48 hours @ 77°F and 50% Relative Humidity
Application Temp.: 40°F to 120°F
Service Temp(Cured Film): 15°F to 180°F
VOC Content: 40 g/L MAX
SURFACE PREPARATION:
All surfaces to be coated should be in sound condition and thoroughly cleaned and free of oil, grease, dust, dirt, debris and loose coating. Pressure wash with 799 Wash-N-Prep Roof Cleaner and water. Rinse surfaces well to remove all soapy residues and allow to dry completely. Metal surfaces must be wire brushed down to clean and stable surface. Repair all roof surfaces with appropriate materials prior to coatings. Read the SDS before using. For questions regarding repairs, surface preparation, or request for an SDS, please contact KARNAK Technical Services at 800-526-4236.
APPLICATION:
Recommended use is for application over one of KARNAK’s 400 series substrate-specific base coats or directly to the substrate in a two-coat application. Mix lightly prior to application of the coating. 529 Renu-White may be applied by brush, spray equipment or roller. Allow first coat to dry 8 to12 hours before application of the second coat. Apply each coat in one direction with the second coat applied perpendicular to the first/base coat. Apply when temperatures are 40ºF and rising but not over 120ºF. Do not apply when rain is expected during or within 24 hours after application. For applications in higher temperatures (above 90 °F) KARNAK recommends application in multiple thin coats to prevent trapped moisture problems. Commencement of work by the contractor implies his approval of the deck surface.
ROLLER / BRUSH APPLICATION:
Apply with a 3/4" – 1-1/4” nap roller or soft roof brush perpendicular to the first coat/base coat for proper protection.
SPRAY APPLICATION:
Utilize a heavy-duty professional airless spray pump. Equipment manufacturer should be consulted for more complete information. Spray application should be done with a 50% overspray pattern.
COVERAGE RATE:
Apply 529 Renu-White in two coats at the rate of 1.5 gallons per 100 sq. ft. (24 wet mils) per coat for a total coverage of 3 gallons per 100 sq. ft. or apply at the rate of 1.5 gallons per 100 sq. ft. over applicable KARNAK 400 series base coat. Do not thin coating. Coverage varies with their regularity and porosity of the roof surface.
ARCHITECTURAL COLORS:
White
Do not apply when rain is imminent. Do not take internally. If swallowed, do not induce vomiting. Call a physician immediately. Keep away from children. Use with adequate ventilation. Avoid prolonged contact with skin. Wash exposed areas promptly with soap and water. Flush eyes with copious amounts of water. Protect from freezing. Product must be dried before exposure to water. Do not thin. Store in a cool, dry place. Dispose of in an environmentally safe manner.
CARE OF TOOLS:
Clean tools with cool, soapy water immediately after use. Dry coating may be cleaned with mineral spirits or similar solvent. Take necessary precautions when handling combustible materials.